Changes:
- Make ServiceMetricEvent.Builder extend ServiceEventBuilder<ServiceMetricEvent>
and thus convert it to a plain builder rather than a builder of builder.
- Add methods setCreatedTime , setMetricAndValue to the builder
Changes:
- Add a metric for partition-wise kafka/kinesis lag for streaming ingestion.
- Emit lag metrics for streaming ingestion when supervisor is not suspended and state is in {RUNNING, IDLE, UNHEALTHY_TASKS, UNHEALTHY_SUPERVISOR}
- Document metrics
* IntelliJ inspection and checkstyle rule for "Collection.EMPTY_* field accesses replaceable with Collections.empty*()"
* Reverted checkstyle rule
* Added tests to pass CI
* Codestyle
* Add config option for namespacePrefix
opentsdb emitter sends metric names to opentsdb verbatim as what druid
names them, for example "query.count", this doesn't fit well with a
central opentsdb server which might have namespaced metrics, for example
"druid.query.count". This adds support for adding an optional prefix.
The prefix also gets a trailing dot (.), after it, so the metric name
becomes <namespacePrefix>.<metricname>
configureable as "druid.emitter.opentsdb.namespacePrefix", as
documented.
Co-authored-by: Martin Gerholm <martin.gerholm@deltaprojects.com>
Signed-off-by: Martin Gerholm <martin.gerholm@deltaprojects.com>
Signed-off-by: Björn Zettergren <bjorn.zettergren@deltaprojects.com>
* Spelling for PR #9372
Added "namespacePrefix" to .spelling exceptions, it's a variable name
used in documentation for opentsdb-emitter.
* fixing tests for PR #9372
changed naming of variables to be more descriptive
added test of prefix being an empty string: "".
added a conditional to buildNamespacePrefix to check for empty string
being fed if EventConverter called without OpentsdbEmitterConfig
instance.
* fixing checkstyle errors for PR #9372
used == to compare literal string, should be equals()
* cleaned up and updated PR #9372
Created a buildMetric function as suggested by clintropolis, and
removed redundant tests for empty strings as they're only used when
calling EventConverter directly without going through
OpentsdbEmitterConfig.
* consistent naming of tests PR #9372
Changed names of tests in files to match better with what it was
actually testing
changed check for Strings.isNullOrEmpty to just check for `null`, as
empty string valued `namespacePrefix` is handled in
OpentsdbEmitterConfig.
Co-authored-by: Martin Gerholm <inspector-martin@users.noreply.github.com>
Make static imports forbidden in tests and remove all occurrences to be
consistent with the non-test code.
Also, various changes to files affected by above:
- Reformat to adhere to druid style guide
- Fix various IntelliJ warnings
- Fix various SonarLint warnings (e.g., the expected/actual args to
Assert.assertEquals() were flipped)
This PR accumulates many refactorings and small improvements that I did while preparing the next change set of https://github.com/druid-io/druid/projects/2. I finally decided to make them a separate PR to minimize the volume of the main PR.
Some of the changes:
- Renamed confusing "Generic Column" term to "Numeric Column" (what it actually implies) in many class names.
- Generified `ComplexMetricExtractor`
* fix opentsdb emitter always be running
* check if emitter started
* add more details about consumeDelay in doc
* fix possible thread unsafe
* fix fail sending tags whose value contain colon
* Rename io.druid to org.apache.druid.
* Fix META-INF files and remove some benchmark results.
* MonitorsConfig update for metrics package migration.
* Reorder some dimensions in inner queries for some reason.
* Fix protobuf tests.
* opentsdb emitter extension
* doc for opentsdb emitter extension
* update opentsdb emitter doc
* add the ms unit to the constant name
* add a configurable event limit
* fix version to 0.13.0-SNAPSHOT
* using a thread to consume metric event
* rename method and parameter