HDFS-7230. Add rolling downgrade documentation. Contributed by Tsz Wo Nicholas Sze.
Conflicts: hadoop-hdfs-project/hadoop-hdfs/CHANGES.txt
This commit is contained in:
parent
e107ea5177
commit
fe1f4c64d1
|
@ -415,6 +415,8 @@ Release 2.6.0 - UNRELEASED
|
|||
HDFS-6988. Improve HDFS-6581 eviction configuration (Xiaoyu Yao via Colin
|
||||
P. McCabe)
|
||||
|
||||
HDFS-7230. Add rolling downgrade documentation. (szetszwo via jing9)
|
||||
|
||||
OPTIMIZATIONS
|
||||
|
||||
HDFS-6690. Deduplicate xattr names in memory. (wang)
|
||||
|
|
|
@ -152,17 +152,21 @@
|
|||
or, in some unlikely case, the upgrade fails (due to bugs in the newer release),
|
||||
administrators may choose to downgrade HDFS back to the pre-upgrade release,
|
||||
or rollback HDFS to the pre-upgrade release and the pre-upgrade state.
|
||||
Both downgrade and rollback require cluster downtime and are not done in a rolling fashion.
|
||||
</p>
|
||||
<p>
|
||||
Note that downgrade and rollback are possible only after a rolling upgrade is started and
|
||||
Note that downgrade can be done in a rolling fashion but rollback cannot.
|
||||
Rollback requires cluster downtime.
|
||||
</p>
|
||||
<p>
|
||||
Note also that downgrade and rollback are possible only after a rolling upgrade is started and
|
||||
before the upgrade is terminated.
|
||||
An upgrade can be terminated by either finalize, downgrade or rollback.
|
||||
Therefore, it may not be possible to perform rollback after finalize or downgrade,
|
||||
or to perform downgrade after finalize.
|
||||
</p>
|
||||
</section>
|
||||
|
||||
<subsection name="Downgrade" id="Downgrade">
|
||||
<section name="Downgrade" id="Downgrade">
|
||||
<p>
|
||||
<em>Downgrade</em> restores the software back to the pre-upgrade release
|
||||
and preserves the user data.
|
||||
|
@ -174,21 +178,70 @@
|
|||
A newer release is downgradable to the pre-upgrade release
|
||||
only if both the namenode layout version and the datenode layout version
|
||||
are not changed between these two releases.
|
||||
Below are the steps for downgrade:
|
||||
</p>
|
||||
<ul>
|
||||
<li>Downgrade HDFS<ol>
|
||||
|
||||
<subsection name="Downgrade without Downtime" id="DowngradeWithoutDowntime">
|
||||
<p>
|
||||
In a HA cluster,
|
||||
when a rolling upgrade from an old software release to a new software release is in progress,
|
||||
it is possible to downgrade, in a rolling fashion, the upgraded machines back to the old software release.
|
||||
Same as before, suppose <em>NN1</em> and <em>NN2</em> are respectively in active and standby states.
|
||||
Below are the steps for rolling downgrade:
|
||||
</p>
|
||||
<ol>
|
||||
<li>Downgrade <em>DNs</em><ol>
|
||||
<li>Choose a small subset of datanodes (e.g. all datanodes under a particular rack).</li>
|
||||
<ol>
|
||||
<li>Run "<code><a href="#dfsadmin_-shutdownDatanode">hdfs dfsadmin -shutdownDatanode <DATANODE_HOST:IPC_PORT> upgrade</a></code>"
|
||||
to shutdown one of the chosen datanodes.</li>
|
||||
<li>Run "<code><a href="#dfsadmin_-getDatanodeInfo">hdfs dfsadmin -getDatanodeInfo <DATANODE_HOST:IPC_PORT></a></code>"
|
||||
to check and wait for the datanode to shutdown.</li>
|
||||
<li>Downgrade and restart the datanode.</li>
|
||||
<li>Perform the above steps for all the chosen datanodes in the subset in parallel.</li>
|
||||
</ol>
|
||||
<li>Repeat the above steps until all upgraded datanodes in the cluster are downgraded.</li>
|
||||
</ol></li>
|
||||
<li>Downgrade Active and Standby <em>NNs</em><ol>
|
||||
<li>Shutdown and downgrade <em>NN2</em>.</li>
|
||||
<li>Start <em>NN2</em> as standby normally. (Note that it is incorrect to use the
|
||||
"<a href="#namenode_-rollingUpgrade"><code>-rollingUpgrade downgrade</code></a>"
|
||||
option here.)
|
||||
</li>
|
||||
<li>Failover from <em>NN1</em> to <em>NN2</em>
|
||||
so that <em>NN2</em> becomes active and <em>NN1</em> becomes standby.</li>
|
||||
<li>Shutdown and upgrade <em>NN1</em>.</li>
|
||||
<li>Start <em>NN1</em> as standby normally. (Note that it is incorrect to use the
|
||||
"<a href="#namenode_-rollingUpgrade"><code>-rollingUpgrade downgrade</code></a>"
|
||||
option here.)
|
||||
</li>
|
||||
</ol></li>
|
||||
<li>Finalize Rolling Downgrade<ul>
|
||||
<li>Run "<code><a href="#dfsadmin_-rollingUpgrade">hdfs dfsadmin -rollingUpgrade finalize</a></code>"
|
||||
to finalize the rolling downgrade.</li>
|
||||
</ul></li>
|
||||
</ol>
|
||||
<p>
|
||||
Note that the datanodes must be downgraded before downgrading the namenodes
|
||||
since protocols may be changed in a backward compatible manner but not forward compatible,
|
||||
i.e. old datanodes can talk to the new namenodes but not vice versa.
|
||||
</p>
|
||||
</subsection>
|
||||
<subsection name="Downgrade with Downtime" id="DowngradeWithDowntime">
|
||||
<p>
|
||||
Administrator may choose to first shutdown the cluster and then downgrade it.
|
||||
The following are the steps:
|
||||
</p>
|
||||
<ol>
|
||||
<li>Shutdown all <em>NNs</em> and <em>DNs</em>.</li>
|
||||
<li>Restore the pre-upgrade release in all machines.</li>
|
||||
<li>Start <em>NNs</em> with the
|
||||
"<a href="#namenode_-rollingUpgrade"><code>-rollingUpgrade downgrade</code></a>" option.</li>
|
||||
<li>Start <em>DNs</em> normally.</li>
|
||||
</ol></li>
|
||||
</ul>
|
||||
|
||||
</ol>
|
||||
</subsection>
|
||||
</section>
|
||||
|
||||
<subsection name="Rollback" id="Rollback">
|
||||
<section name="Rollback" id="Rollback">
|
||||
<p>
|
||||
<em>Rollback</em> restores the software back to the pre-upgrade release
|
||||
but also reverts the user data back to the pre-upgrade state.
|
||||
|
@ -198,6 +251,7 @@
|
|||
</p>
|
||||
<p>
|
||||
Rollback from a newer release to the pre-upgrade release is always supported.
|
||||
However, it cannot be done in a rolling fashion. It requires cluster downtime.
|
||||
Below are the steps for rollback:
|
||||
</p>
|
||||
<ul>
|
||||
|
@ -210,7 +264,6 @@
|
|||
</ol></li>
|
||||
</ul>
|
||||
|
||||
</subsection>
|
||||
</section>
|
||||
|
||||
<section name="Commands and Startup Options for Rolling Upgrade" id="dfsadminCommands">
|
||||
|
@ -248,7 +301,7 @@
|
|||
<p>
|
||||
Note that the command does not wait for the datanode shutdown to complete.
|
||||
The "<a href="#dfsadmin_-getDatanodeInfo">dfsadmin -getDatanodeInfo</a>"
|
||||
command can be used for checking if the datanode shutdown is complete.
|
||||
command can be used for checking if the datanode shutdown is completed.
|
||||
</p>
|
||||