[GF#21472]: org.hl7.fhir.core: Validator cannot validate BP Profile
This commit is contained in:
parent
62ec11aad2
commit
30803a7a41
|
@ -468,6 +468,32 @@
|
||||||
"errorCount": 0
|
"errorCount": 0
|
||||||
}
|
}
|
||||||
},
|
},
|
||||||
|
"observation-bp-validationfails.xml" : {
|
||||||
|
"errorCount": 4,
|
||||||
|
"errors": [
|
||||||
|
"ERROR: Observation.component[1]: Error in discriminator at Observation.component:SystolicBP.code.coding: slicing found",
|
||||||
|
"ERROR: Observation.component[2]: Error in discriminator at Observation.component:SystolicBP.code.coding: slicing found",
|
||||||
|
"ERROR: Observation.component[1]: Error in discriminator at Observation.component:DiastolicBP.code.coding: slicing found",
|
||||||
|
"ERROR: Observation.component[2]: Error in discriminator at Observation.component:DiastolicBP.code.coding: slicing found"
|
||||||
|
]
|
||||||
|
},
|
||||||
|
"observation-bp.xml" : {
|
||||||
|
"errorCount": 0,
|
||||||
|
"profile" : {
|
||||||
|
"source" : "observation-bp-profile.xml",
|
||||||
|
"errorCount": 0
|
||||||
|
}
|
||||||
|
},
|
||||||
|
"observation-bp-bad-onlydiastolic.xml" : {
|
||||||
|
"errorCount": 0,
|
||||||
|
"profile" : {
|
||||||
|
"source" : "observation-bp-profile.xml",
|
||||||
|
"errorCount": 1,
|
||||||
|
"errors": [
|
||||||
|
"ERROR: Observation: Profile http://hl7.org/fhir/StructureDefinition/observation-bp-profile, Element 'Observation.component[SystolicBP]': minimum required = 1, but only found 0"
|
||||||
|
]
|
||||||
|
}
|
||||||
|
},
|
||||||
"observation-cholesterol-good.xml" : {
|
"observation-cholesterol-good.xml" : {
|
||||||
"errorCount": 0
|
"errorCount": 0
|
||||||
},
|
},
|
||||||
|
|
|
@ -0,0 +1,250 @@
|
||||||
|
<Observation xmlns="http://hl7.org/fhir">
|
||||||
|
<!-- extract from https://www.hl7.org/fhir/observation-example-bloodpressure.xml,
|
||||||
|
changed id from blood-pressure to observation-bp and removed systolic loinc coide that observation fails -->
|
||||||
|
<id value="observation-bp-bad-onlydiastolic" />
|
||||||
|
<text>
|
||||||
|
<status value="generated" />
|
||||||
|
<div xmlns="http://www.w3.org/1999/xhtml">
|
||||||
|
<p>
|
||||||
|
<b>Generated Narrative with Details</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>id</b>
|
||||||
|
: blood-pressure
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>meta</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>identifier</b>
|
||||||
|
: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>basedOn</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>status</b>
|
||||||
|
: final
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>category</b>
|
||||||
|
: Vital Signs
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/observation-category code
|
||||||
|
'vital-signs' = 'Vital Signs', given as 'Vital
|
||||||
|
Signs'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>:
|
||||||
|
Blood pressure systolic & diastolic
|
||||||
|
<span>(Details : {LOINC code '85354-9' = 'Blood pressure
|
||||||
|
panel with all children optional', given as 'Blood pressure
|
||||||
|
panel with all children optional'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>subject</b>
|
||||||
|
:
|
||||||
|
<a>Patient/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>effective</b>
|
||||||
|
: 17/09/2012
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>performer</b>
|
||||||
|
:
|
||||||
|
<a>Practitioner/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>bodySite</b>
|
||||||
|
: Right arm
|
||||||
|
<span>(Details : {SNOMED CT code '368209003' = 'Right
|
||||||
|
upper arm', given as 'Right arm'})</span>
|
||||||
|
</p>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Systolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8480-6' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{SNOMED CT code '271649006' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{http://acme.org/devices/clinical-codes code 'bp-s' =
|
||||||
|
'bp-s', given as 'Systolic Blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 107 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'N' = 'Normal', given as 'normal'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Diastolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8462-4' = 'Diastolic
|
||||||
|
blood pressure', given as 'Diastolic blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 60 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
</div>
|
||||||
|
</text>
|
||||||
|
<identifier>
|
||||||
|
<system value="urn:ietf:rfc:3986" />
|
||||||
|
<value value="urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" />
|
||||||
|
</identifier><!-- demonstrating the use of the baseOn element with a fictive
|
||||||
|
identifier -->
|
||||||
|
<basedOn>
|
||||||
|
<identifier>
|
||||||
|
<system value="https://acme.org/identifiers" />
|
||||||
|
<value value="1234" />
|
||||||
|
</identifier>
|
||||||
|
</basedOn>
|
||||||
|
<status value="final" />
|
||||||
|
<category>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/observation-category" />
|
||||||
|
<code value="vital-signs" />
|
||||||
|
<display value="Vital Signs" />
|
||||||
|
</coding>
|
||||||
|
</category>
|
||||||
|
<code><!-- replaced by 85354-9 <coding> <system value="http://loinc.org"/>
|
||||||
|
<code value="85354-9"/> <display value="Blood pressure systolic & diastolic"/>
|
||||||
|
</coding> -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="85354-9" />
|
||||||
|
<display
|
||||||
|
value="Blood pressure panel with all children optional" />
|
||||||
|
</coding>
|
||||||
|
<text value="Blood pressure systolic & diastolic" />
|
||||||
|
</code>
|
||||||
|
<subject>
|
||||||
|
<reference value="Patient/example" />
|
||||||
|
</subject>
|
||||||
|
<effectiveDateTime value="2012-09-17" />
|
||||||
|
<performer>
|
||||||
|
<reference value="Practitioner/example" />
|
||||||
|
</performer><!-- an interpretation offered to the combination observation
|
||||||
|
generally, it would only be appropriate to offer an interpretation of an
|
||||||
|
observation that has no value if it has "COMP" (component) observations -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- The BodySite can be captured in a LOINC code but am
|
||||||
|
showing it here to demonstrate populating the element -->
|
||||||
|
<bodySite>
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="368209003" />
|
||||||
|
<display value="Right arm" />
|
||||||
|
</coding>
|
||||||
|
</bodySite>
|
||||||
|
<component><!-- Observations are often coded in multiple code systems. -
|
||||||
|
LOINC provides a very specific code (though not more specific in this particular
|
||||||
|
case) - snomed provides a clinically relevant code that is usually less granular
|
||||||
|
than LOINC - the source system provides its own code, which may be less or
|
||||||
|
more granular than LOINC this is shown here to demonstrate the concept of
|
||||||
|
translations within the codeableConcept datatype. The diastolic code below
|
||||||
|
only has a LOINC code -->
|
||||||
|
<code><!-- LOINC -code -->
|
||||||
|
<!-- removed systolic loinc coide that observation fails <coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8480-6" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding>
|
||||||
|
--> <!-- SNOMED CT Codes -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="271649006" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding><!-- Also, a local code specific to the source system -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://acme.org/devices/clinical-codes" />
|
||||||
|
<code value="bp-s" />
|
||||||
|
<display value="Systolic Blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="107" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="N" />
|
||||||
|
<display value="normal" />
|
||||||
|
</coding>
|
||||||
|
<text value="Normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
<component><!-- this codes only has a LOINC code -->
|
||||||
|
<code>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8462-4" />
|
||||||
|
<display value="Diastolic blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="60" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
</Observation>
|
|
@ -0,0 +1,243 @@
|
||||||
|
<StructureDefinition xmlns="http://hl7.org/fhir">
|
||||||
|
<id value="observation-bp-profile" />
|
||||||
|
<text>
|
||||||
|
<status value="generated" />
|
||||||
|
<div xmlns="http://www.w3.org/1999/xhtml">reworked official bp profile to use patternCodeableConcept</div>
|
||||||
|
</text>
|
||||||
|
<url value="http://hl7.org/fhir/StructureDefinition/observation-bp-profile" />
|
||||||
|
<version value="4.0.0" />
|
||||||
|
<name value="observation-bp" />
|
||||||
|
<title value="Observation Blood Pressure Profile" />
|
||||||
|
<status value="draft" />
|
||||||
|
<experimental value="false" />
|
||||||
|
<date value="2019-05-06" />
|
||||||
|
<publisher
|
||||||
|
value="Health Level Seven International (Orders and Observations Workgroup)" />
|
||||||
|
<contact>
|
||||||
|
<telecom>
|
||||||
|
<system value="url" />
|
||||||
|
<value
|
||||||
|
value="http://www.hl7.org/Special/committees/orders/index.cfm Orders and Observations" />
|
||||||
|
</telecom>
|
||||||
|
</contact>
|
||||||
|
<description value="FHIR Blood Pressure Profile" />
|
||||||
|
<fhirVersion value="4.0.0" />
|
||||||
|
<mapping>
|
||||||
|
<identity value="workflow" />
|
||||||
|
<uri value="http://hl7.org/fhir/workflow" />
|
||||||
|
<name value="Workflow Pattern" />
|
||||||
|
</mapping>
|
||||||
|
<mapping>
|
||||||
|
<identity value="sct-concept" />
|
||||||
|
<uri value="http://snomed.info/conceptdomain" />
|
||||||
|
<name value="SNOMED CT Concept Domain Binding" />
|
||||||
|
</mapping>
|
||||||
|
<mapping>
|
||||||
|
<identity value="v2" />
|
||||||
|
<uri value="http://hl7.org/v2" />
|
||||||
|
<name value="HL7 v2 Mapping" />
|
||||||
|
</mapping>
|
||||||
|
<mapping>
|
||||||
|
<identity value="rim" />
|
||||||
|
<uri value="http://hl7.org/v3" />
|
||||||
|
<name value="RIM Mapping" />
|
||||||
|
</mapping>
|
||||||
|
<mapping>
|
||||||
|
<identity value="w5" />
|
||||||
|
<uri value="http://hl7.org/fhir/fivews" />
|
||||||
|
<name value="FiveWs Pattern Mapping" />
|
||||||
|
</mapping>
|
||||||
|
<mapping>
|
||||||
|
<identity value="sct-attr" />
|
||||||
|
<uri value="http://snomed.org/attributebinding" />
|
||||||
|
<name value="SNOMED CT Attribute Binding" />
|
||||||
|
</mapping>
|
||||||
|
<kind value="resource" />
|
||||||
|
<abstract value="false" />
|
||||||
|
<type value="Observation" />
|
||||||
|
<baseDefinition
|
||||||
|
value="http://hl7.org/fhir/StructureDefinition/vitalsigns" />
|
||||||
|
<derivation value="constraint" />
|
||||||
|
<differential>
|
||||||
|
<element id="Observation">
|
||||||
|
<path value="Observation" />
|
||||||
|
<short value="FHIR Blood Pressure Profile" />
|
||||||
|
<definition
|
||||||
|
value="This profile defines how to represent Blood Pressure observations in FHIR using a standard LOINC code and UCUM units of measure. This is a grouping structure. It has no value in Observation.valueQuantity but contains at least one component (systolic and/or diastolic)." />
|
||||||
|
<min value="0" />
|
||||||
|
<max value="*" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.code">
|
||||||
|
<path value="Observation.code" />
|
||||||
|
<short value="Blood Pressure" />
|
||||||
|
<definition value="Blood Pressure" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="CodeableConcept" />
|
||||||
|
</type>
|
||||||
|
<patternCodeableConcept>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="85354-9" />
|
||||||
|
</coding>
|
||||||
|
</patternCodeableConcept>
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.valueQuantity">
|
||||||
|
<path value="Observation.valueQuantity" />
|
||||||
|
<min value="0" />
|
||||||
|
<max value="0" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component">
|
||||||
|
<path value="Observation.component" />
|
||||||
|
<slicing>
|
||||||
|
<discriminator>
|
||||||
|
<type value="pattern" />
|
||||||
|
<path value="code" />
|
||||||
|
</discriminator>
|
||||||
|
<rules value="open" />
|
||||||
|
</slicing>
|
||||||
|
<min value="2" />
|
||||||
|
<max value="*" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:SystolicBP">
|
||||||
|
<path value="Observation.component" />
|
||||||
|
<sliceName value="SystolicBP" />
|
||||||
|
<short value="SystolicBP" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:SystolicBP.code">
|
||||||
|
<path value="Observation.component.code" />
|
||||||
|
<min value="1" />
|
||||||
|
<patternCodeableConcept>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8480-6" />
|
||||||
|
</coding>
|
||||||
|
</patternCodeableConcept>
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:SystolicBP.valueQuantity">
|
||||||
|
<path value="Observation.component.valueQuantity" />
|
||||||
|
<type>
|
||||||
|
<code value="Quantity" />
|
||||||
|
</type>
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:SystolicBP.valueQuantity.value">
|
||||||
|
<path value="Observation.component.valueQuantity.value" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="decimal" />
|
||||||
|
</type>
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:SystolicBP.valueQuantity.unit">
|
||||||
|
<path value="Observation.component.valueQuantity.unit" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="string" />
|
||||||
|
</type>
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:SystolicBP.valueQuantity.system">
|
||||||
|
<path value="Observation.component.valueQuantity.system" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="uri" />
|
||||||
|
</type>
|
||||||
|
<fixedUri value="http://unitsofmeasure.org" />
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:SystolicBP.valueQuantity.code">
|
||||||
|
<path value="Observation.component.valueQuantity.code" />
|
||||||
|
<short
|
||||||
|
value="Coded responses from the common UCUM units for vital signs value set." />
|
||||||
|
<definition
|
||||||
|
value="Coded responses from the common UCUM units for vital signs value set." />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="code" />
|
||||||
|
</type>
|
||||||
|
<fixedCode value="mm[Hg]" />
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:DiastolicBP">
|
||||||
|
<path value="Observation.component" />
|
||||||
|
<sliceName value="DiastolicBP" />
|
||||||
|
<short value="DiastolicBP" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:DiastolicBP">
|
||||||
|
<path value="Observation.component.code" />
|
||||||
|
<min value="1" />
|
||||||
|
<patternCodeableConcept>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8462-4" />
|
||||||
|
</coding>
|
||||||
|
</patternCodeableConcept>
|
||||||
|
</element>
|
||||||
|
<element id="Observation.component:DiastolicBP.valueQuantity">
|
||||||
|
<path value="Observation.component.valueQuantity" />
|
||||||
|
<type>
|
||||||
|
<code value="Quantity" />
|
||||||
|
</type>
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:DiastolicBP.valueQuantity.value">
|
||||||
|
<path value="Observation.component.valueQuantity.value" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="decimal" />
|
||||||
|
</type>
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:DiastolicBP.valueQuantity.unit">
|
||||||
|
<path value="Observation.component.valueQuantity.unit" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="string" />
|
||||||
|
</type>
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:DiastolicBP.valueQuantity.system">
|
||||||
|
<path value="Observation.component.valueQuantity.system" />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="uri" />
|
||||||
|
</type>
|
||||||
|
<fixedUri value="http://unitsofmeasure.org" />
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
<element
|
||||||
|
id="Observation.component:DiastolicBP.valueQuantity.code">
|
||||||
|
<path value="Observation.component.valueQuantity.code" />
|
||||||
|
<short
|
||||||
|
value="Coded responses from the common UCUM units for vital signs value set." />
|
||||||
|
<definition
|
||||||
|
value="Coded responses from the common UCUM units for vital signs value set." />
|
||||||
|
<min value="1" />
|
||||||
|
<max value="1" />
|
||||||
|
<type>
|
||||||
|
<code value="code" />
|
||||||
|
</type>
|
||||||
|
<fixedCode value="mm[Hg]" />
|
||||||
|
<mustSupport value="true" />
|
||||||
|
</element>
|
||||||
|
</differential>
|
||||||
|
</StructureDefinition>
|
|
@ -0,0 +1,253 @@
|
||||||
|
<Observation xmlns="http://hl7.org/fhir">
|
||||||
|
<!-- extract from https://www.hl7.org/fhir/observation-example-bloodpressure.xml,
|
||||||
|
changed id from blood-pressure to observation-bp-validationfails and added explicit profile
|
||||||
|
reference to http://hl7.org/fhir/StructureDefinition/bp -->
|
||||||
|
<id value="observation-bp-validationfails" />
|
||||||
|
<meta>
|
||||||
|
<profile value="http://hl7.org/fhir/StructureDefinition/bp" />
|
||||||
|
</meta>
|
||||||
|
<text>
|
||||||
|
<status value="generated" />
|
||||||
|
<div xmlns="http://www.w3.org/1999/xhtml">
|
||||||
|
<p>
|
||||||
|
<b>Generated Narrative with Details</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>id</b>
|
||||||
|
: blood-pressure
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>meta</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>identifier</b>
|
||||||
|
: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>basedOn</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>status</b>
|
||||||
|
: final
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>category</b>
|
||||||
|
: Vital Signs
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/observation-category code
|
||||||
|
'vital-signs' = 'Vital Signs', given as 'Vital
|
||||||
|
Signs'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>:
|
||||||
|
Blood pressure systolic & diastolic
|
||||||
|
<span>(Details : {LOINC code '85354-9' = 'Blood pressure
|
||||||
|
panel with all children optional', given as 'Blood pressure
|
||||||
|
panel with all children optional'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>subject</b>
|
||||||
|
:
|
||||||
|
<a>Patient/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>effective</b>
|
||||||
|
: 17/09/2012
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>performer</b>
|
||||||
|
:
|
||||||
|
<a>Practitioner/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>bodySite</b>
|
||||||
|
: Right arm
|
||||||
|
<span>(Details : {SNOMED CT code '368209003' = 'Right
|
||||||
|
upper arm', given as 'Right arm'})</span>
|
||||||
|
</p>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Systolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8480-6' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{SNOMED CT code '271649006' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{http://acme.org/devices/clinical-codes code 'bp-s' =
|
||||||
|
'bp-s', given as 'Systolic Blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 107 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'N' = 'Normal', given as 'normal'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Diastolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8462-4' = 'Diastolic
|
||||||
|
blood pressure', given as 'Diastolic blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 60 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
</div>
|
||||||
|
</text>
|
||||||
|
<identifier>
|
||||||
|
<system value="urn:ietf:rfc:3986" />
|
||||||
|
<value value="urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" />
|
||||||
|
</identifier><!-- demonstrating the use of the baseOn element with a fictive
|
||||||
|
identifier -->
|
||||||
|
<basedOn>
|
||||||
|
<identifier>
|
||||||
|
<system value="https://acme.org/identifiers" />
|
||||||
|
<value value="1234" />
|
||||||
|
</identifier>
|
||||||
|
</basedOn>
|
||||||
|
<status value="final" />
|
||||||
|
<category>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/observation-category" />
|
||||||
|
<code value="vital-signs" />
|
||||||
|
<display value="Vital Signs" />
|
||||||
|
</coding>
|
||||||
|
</category>
|
||||||
|
<code><!-- replaced by 85354-9 <coding> <system value="http://loinc.org"/>
|
||||||
|
<code value="85354-9"/> <display value="Blood pressure systolic & diastolic"/>
|
||||||
|
</coding> -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="85354-9" />
|
||||||
|
<display
|
||||||
|
value="Blood pressure panel with all children optional" />
|
||||||
|
</coding>
|
||||||
|
<text value="Blood pressure systolic & diastolic" />
|
||||||
|
</code>
|
||||||
|
<subject>
|
||||||
|
<reference value="Patient/example" />
|
||||||
|
</subject>
|
||||||
|
<effectiveDateTime value="2012-09-17" />
|
||||||
|
<performer>
|
||||||
|
<reference value="Practitioner/example" />
|
||||||
|
</performer><!-- an interpretation offered to the combination observation
|
||||||
|
generally, it would only be appropriate to offer an interpretation of an
|
||||||
|
observation that has no value if it has "COMP" (component) observations -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- The BodySite can be captured in a LOINC code but am
|
||||||
|
showing it here to demonstrate populating the element -->
|
||||||
|
<bodySite>
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="368209003" />
|
||||||
|
<display value="Right arm" />
|
||||||
|
</coding>
|
||||||
|
</bodySite>
|
||||||
|
<component><!-- Observations are often coded in multiple code systems. -
|
||||||
|
LOINC provides a very specific code (though not more specific in this particular
|
||||||
|
case) - snomed provides a clinically relevant code that is usually less granular
|
||||||
|
than LOINC - the source system provides its own code, which may be less or
|
||||||
|
more granular than LOINC this is shown here to demonstrate the concept of
|
||||||
|
translations within the codeableConcept datatype. The diastolic code below
|
||||||
|
only has a LOINC code -->
|
||||||
|
<code><!-- LOINC -code -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8480-6" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding><!-- SNOMED CT Codes -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="271649006" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding><!-- Also, a local code specific to the source system -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://acme.org/devices/clinical-codes" />
|
||||||
|
<code value="bp-s" />
|
||||||
|
<display value="Systolic Blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="107" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="N" />
|
||||||
|
<display value="normal" />
|
||||||
|
</coding>
|
||||||
|
<text value="Normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
<component><!-- this codes only has a LOINC code -->
|
||||||
|
<code>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8462-4" />
|
||||||
|
<display value="Diastolic blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="60" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
</Observation>
|
|
@ -0,0 +1,249 @@
|
||||||
|
<Observation xmlns="http://hl7.org/fhir">
|
||||||
|
<!-- extract from https://www.hl7.org/fhir/observation-example-bloodpressure.xml,
|
||||||
|
changed id from blood-pressure to observation-bp -->
|
||||||
|
<id value="observation-bp" />
|
||||||
|
<text>
|
||||||
|
<status value="generated" />
|
||||||
|
<div xmlns="http://www.w3.org/1999/xhtml">
|
||||||
|
<p>
|
||||||
|
<b>Generated Narrative with Details</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>id</b>
|
||||||
|
: blood-pressure
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>meta</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>identifier</b>
|
||||||
|
: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>basedOn</b>
|
||||||
|
:
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>status</b>
|
||||||
|
: final
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>category</b>
|
||||||
|
: Vital Signs
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/observation-category code
|
||||||
|
'vital-signs' = 'Vital Signs', given as 'Vital
|
||||||
|
Signs'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>:
|
||||||
|
Blood pressure systolic & diastolic
|
||||||
|
<span>(Details : {LOINC code '85354-9' = 'Blood pressure
|
||||||
|
panel with all children optional', given as 'Blood pressure
|
||||||
|
panel with all children optional'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>subject</b>
|
||||||
|
:
|
||||||
|
<a>Patient/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>effective</b>
|
||||||
|
: 17/09/2012
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>performer</b>
|
||||||
|
:
|
||||||
|
<a>Practitioner/example</a>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>bodySite</b>
|
||||||
|
: Right arm
|
||||||
|
<span>(Details : {SNOMED CT code '368209003' = 'Right
|
||||||
|
upper arm', given as 'Right arm'})</span>
|
||||||
|
</p>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Systolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8480-6' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{SNOMED CT code '271649006' = 'Systolic blood
|
||||||
|
pressure', given as 'Systolic blood pressure'};
|
||||||
|
{http://acme.org/devices/clinical-codes code 'bp-s' =
|
||||||
|
'bp-s', given as 'Systolic Blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 107 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'N' = 'Normal', given as 'normal'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
<blockquote>
|
||||||
|
<p>
|
||||||
|
<b>component</b>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>code</b>
|
||||||
|
: Diastolic blood pressure
|
||||||
|
<span>(Details : {LOINC code '8462-4' = 'Diastolic
|
||||||
|
blood pressure', given as 'Diastolic blood pressure'})
|
||||||
|
</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>value</b>
|
||||||
|
: 60 mmHg
|
||||||
|
<span> (Details: UCUM code mm[Hg] = 'mmHg')</span>
|
||||||
|
</p>
|
||||||
|
<p>
|
||||||
|
<b>interpretation</b>
|
||||||
|
: Below low normal
|
||||||
|
<span>(Details :
|
||||||
|
{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation
|
||||||
|
code 'L' = 'Low', given as 'low'})</span>
|
||||||
|
</p>
|
||||||
|
</blockquote>
|
||||||
|
</div>
|
||||||
|
</text>
|
||||||
|
<identifier>
|
||||||
|
<system value="urn:ietf:rfc:3986" />
|
||||||
|
<value value="urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" />
|
||||||
|
</identifier><!-- demonstrating the use of the baseOn element with a fictive
|
||||||
|
identifier -->
|
||||||
|
<basedOn>
|
||||||
|
<identifier>
|
||||||
|
<system value="https://acme.org/identifiers" />
|
||||||
|
<value value="1234" />
|
||||||
|
</identifier>
|
||||||
|
</basedOn>
|
||||||
|
<status value="final" />
|
||||||
|
<category>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/observation-category" />
|
||||||
|
<code value="vital-signs" />
|
||||||
|
<display value="Vital Signs" />
|
||||||
|
</coding>
|
||||||
|
</category>
|
||||||
|
<code><!-- replaced by 85354-9 <coding> <system value="http://loinc.org"/>
|
||||||
|
<code value="85354-9"/> <display value="Blood pressure systolic & diastolic"/>
|
||||||
|
</coding> -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="85354-9" />
|
||||||
|
<display
|
||||||
|
value="Blood pressure panel with all children optional" />
|
||||||
|
</coding>
|
||||||
|
<text value="Blood pressure systolic & diastolic" />
|
||||||
|
</code>
|
||||||
|
<subject>
|
||||||
|
<reference value="Patient/example" />
|
||||||
|
</subject>
|
||||||
|
<effectiveDateTime value="2012-09-17" />
|
||||||
|
<performer>
|
||||||
|
<reference value="Practitioner/example" />
|
||||||
|
</performer><!-- an interpretation offered to the combination observation
|
||||||
|
generally, it would only be appropriate to offer an interpretation of an
|
||||||
|
observation that has no value if it has "COMP" (component) observations -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- The BodySite can be captured in a LOINC code but am
|
||||||
|
showing it here to demonstrate populating the element -->
|
||||||
|
<bodySite>
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="368209003" />
|
||||||
|
<display value="Right arm" />
|
||||||
|
</coding>
|
||||||
|
</bodySite>
|
||||||
|
<component><!-- Observations are often coded in multiple code systems. -
|
||||||
|
LOINC provides a very specific code (though not more specific in this particular
|
||||||
|
case) - snomed provides a clinically relevant code that is usually less granular
|
||||||
|
than LOINC - the source system provides its own code, which may be less or
|
||||||
|
more granular than LOINC this is shown here to demonstrate the concept of
|
||||||
|
translations within the codeableConcept datatype. The diastolic code below
|
||||||
|
only has a LOINC code -->
|
||||||
|
<code><!-- LOINC -code -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8480-6" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding><!-- SNOMED CT Codes -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://snomed.info/sct" />
|
||||||
|
<code value="271649006" />
|
||||||
|
<display value="Systolic blood pressure" />
|
||||||
|
</coding><!-- Also, a local code specific to the source system -->
|
||||||
|
<coding>
|
||||||
|
<system value="http://acme.org/devices/clinical-codes" />
|
||||||
|
<code value="bp-s" />
|
||||||
|
<display value="Systolic Blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="107" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="N" />
|
||||||
|
<display value="normal" />
|
||||||
|
</coding>
|
||||||
|
<text value="Normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
<component><!-- this codes only has a LOINC code -->
|
||||||
|
<code>
|
||||||
|
<coding>
|
||||||
|
<system value="http://loinc.org" />
|
||||||
|
<code value="8462-4" />
|
||||||
|
<display value="Diastolic blood pressure" />
|
||||||
|
</coding>
|
||||||
|
</code>
|
||||||
|
<valueQuantity>
|
||||||
|
<value value="60" />
|
||||||
|
<unit value="mmHg" />
|
||||||
|
<system value="http://unitsofmeasure.org" />
|
||||||
|
<code value="mm[Hg]" />
|
||||||
|
</valueQuantity><!-- an interpretation for the individual composite observation -->
|
||||||
|
<interpretation>
|
||||||
|
<coding>
|
||||||
|
<system
|
||||||
|
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" />
|
||||||
|
<code value="L" />
|
||||||
|
<display value="low" />
|
||||||
|
</coding>
|
||||||
|
<text value="Below low normal" />
|
||||||
|
</interpretation><!-- Should have a refrange as well -->
|
||||||
|
</component>
|
||||||
|
</Observation>
|
Loading…
Reference in New Issue