make restart command work correctly even if user has their own check command
This commit is contained in:
parent
52fc0100eb
commit
d81871171c
|
@ -17,7 +17,7 @@ import (
|
|||
)
|
||||
|
||||
var DefaultRestartCommand = "shutdown /r /f /t 0 /c \"packer restart\""
|
||||
var DefaultRestartCheckCommand = winrm.Powershell(`if (Test-Path variable:global:ProgressPreference){$ProgressPreference='SilentlyContinue'}; echo "${env:COMPUTERNAME} restarted."`)
|
||||
var DefaultRestartCheckCommand = winrm.Powershell(`echo "${env:COMPUTERNAME} restarted."`)
|
||||
var retryableSleep = 5 * time.Second
|
||||
var TryCheckReboot = "shutdown.exe -f -r -t 60"
|
||||
var AbortReboot = "shutdown.exe -a"
|
||||
|
@ -174,28 +174,40 @@ WaitLoop:
|
|||
}
|
||||
|
||||
var waitForCommunicator = func(p *Provisioner) error {
|
||||
runCustomRestartCheck := true
|
||||
for {
|
||||
cmd := &packer.RemoteCmd{Command: p.config.RestartCheckCommand}
|
||||
var buf, buf2 bytes.Buffer
|
||||
cmd.Stdout = &buf
|
||||
cmd.Stdout = io.MultiWriter(cmd.Stdout, &buf2)
|
||||
select {
|
||||
case <-p.cancel:
|
||||
log.Println("Communicator wait canceled, exiting loop")
|
||||
return fmt.Errorf("Communicator wait canceled")
|
||||
case <-time.After(retryableSleep):
|
||||
}
|
||||
if runCustomRestartCheck == true {
|
||||
if p.config.RestartCheckCommand == DefaultRestartCheckCommand {
|
||||
runCustomRestartCheck = false
|
||||
}
|
||||
// this is the user configurable command
|
||||
cmdRestartCheck := &packer.RemoteCmd{Command: p.config.RestartCheckCommand}
|
||||
log.Printf("Checking that communicator is connected with: '%s'",
|
||||
cmdRestartCheck.Command)
|
||||
// run user-configured restart check
|
||||
err := cmdRestartCheck.StartWithUi(p.comm, p.ui)
|
||||
|
||||
log.Printf("Checking that communicator is connected with: '%s'", cmd.Command)
|
||||
|
||||
err := cmd.StartWithUi(p.comm, p.ui)
|
||||
|
||||
if err != nil {
|
||||
log.Printf("Communication connection err: %s", err)
|
||||
continue
|
||||
if err != nil {
|
||||
log.Printf("Communication connection err: %s", err)
|
||||
continue
|
||||
}
|
||||
log.Printf("Connected to machine")
|
||||
runCustomRestartCheck = false
|
||||
}
|
||||
// this is the non-user-configurable check that powershell
|
||||
// modules have loaded
|
||||
cmdModuleLoad := &packer.RemoteCmd{Command: DefaultRestartCheckCommand}
|
||||
var buf, buf2 bytes.Buffer
|
||||
cmdModuleLoad.Stdout = &buf
|
||||
cmdModuleLoad.Stdout = io.MultiWriter(cmdModuleLoad.Stdout, &buf2)
|
||||
|
||||
log.Printf("Connected to machine")
|
||||
cmdModuleLoad.StartWithUi(p.comm, p.ui)
|
||||
stdoutToRead := buf2.String()
|
||||
if !strings.Contains(stdoutToRead, "restarted.") {
|
||||
log.Printf("echo didn't succeed; retrying...")
|
||||
|
|
Loading…