VistA-FOIAVistA/r/AUTOMATED_LAB_INSTRUMENTS-LA/LAC178.m

27 lines
1.1 KiB
Mathematica

LAC178 ;SLC/RWF - CORNING 178 BLOOD GAS ;7/20/90 07:41 ;
;;5.2;AUTOMATED LAB INSTRUMENTS;;Sep 27, 1994
;Use in output only mode Brd #6 SW s1-1 closed
;Run in the SEQUENCE mode only Cross link by ID
LA1 S:$D(ZTQUEUED) ZTREQ="@"
S LANM=$T(+0),TSK=$O(^LAB(62.4,"C",LANM,0)) Q:TSK<1
Q:'$D(^LA(TSK,"I",0))
K LATOP D ^LASET Q:'TSK S X="TRAP^"_LANM,@^%ZOSF("TRAP")
LA2 K TV,Y S TOUT=0,A=1 D IN G QUIT:TOUT,LA2:"SYR^CAP^UPD^"'[$E(IN,1,3) D QC
S TOUT=0,BAD=0 F A=2:1:11 D IN,QC G QUIT:TOUT
F I=0:0 S I=$O(TC(I)) Q:I<1 X TC(I,2) S @TC(I,1)=V
S ID=1,TRAY=1,CUP=1
LA3 X LAGEN G LA2:'ISQN ;Can be changed by the cross-link code
F I=0:0 S I=$O(TV(I)) Q:I<1 S:TV(I,1)]"" ^LAH(LWL,1,ISQN,I)=TV(I,1)
G LA2
QC ;QC TESTING HERE; S BAD=1 IF DONT STORE
S Y(A)=IN Q
NUM S X="" F JJ=1:1:$L(V) S:$A(V,JJ)>32 X=X_$E(V,JJ)
S V=X Q
IN S CNT=^LA(TSK,"I",0)+1 IF '$D(^(CNT)) S TOUT=TOUT+1 Q:TOUT>9 H 5 G IN
S ^LA(TSK,"I",0)=CNT,IN=^(CNT),TOUT=0
S:IN["~" CTRL=$P(IN,"~",2),IN=$P(IN,"~",1)
Q
QUIT LOCK ^LA(TSK) H 1 K ^LA(TSK),^LA("LOCK",TSK),^TMP($J),^TMP("LA",$J)
Q
TRAP D ^LABERR S T=TSK D SET^LAB G @("LA2^"_LANM) ;ERROR TRAP