ENEQMED2 ;WISC/SAB-Multiple Equipment Edit, continued ;9/24/97
|
|
;;7.0;ENGINEERING;**35,39,45**;Aug 17, 1993
|
|
UPD ; update equipment
|
|
S DIR(0)="Y",DIR("A")="OK to update the "_ENC("SEL")_" selected items"
|
|
D ^DIR K DIR G:$D(DIRUT)!'Y EXIT
|
|
;
|
|
S ENDA=0 F S ENDA=$O(^TMP($J,"ENSEL",ENDA)) Q:'ENDA D
|
|
. ; lock individual item when not locking as batch; skip if unable
|
|
. I 'ENLOCK("BATCH") L +^ENG(6914,ENDA):1 I '$T D Q
|
|
. . S ^TMP($J,"ENLCK",ENDA)="" ; put skipped equipment on list
|
|
. S ENFLD=0 F S ENFLD=$O(^TMP($J,"ENFLD",ENFLD)) Q:'ENFLD D
|
|
. . S ENFLDN=$$GET1^DID(6914,ENFLD,"","LABEL")
|
|
. . S ENVALI=$P(^TMP($J,"ENFLD",ENFLD),U)
|
|
. . I ENFLD=30 D Q ; pm data
|
|
. . . ; delete old PM data (if any)
|
|
. . . S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDA,4,ENDAPM)) Q:'ENDAPM D
|
|
. . . . K DA S DA(1)=ENDA,DA=ENDAPM,DIK="^ENG(6914,"_ENDA_",4,"
|
|
. . . . D ^DIK K DIK
|
|
. . . ; move new PM data via %RCR
|
|
. . . S ENDAT=$G(^TMP($J,"ENFLD",30)) Q:'ENDAT
|
|
. . . S %X="^ENG(6914,"_ENDAT_",4,",%Y="^ENG(6914,"_ENDA_",4,"
|
|
. . . D %XY^%RCR
|
|
. . . ; reindex PM data
|
|
. . . S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDA,ENDAPM)) Q:'ENDAPM D
|
|
. . . . K DA S DA(1)=ENDA,DA=ENDAPM,DIK="^ENG(6914,"_ENDA_",4,"
|
|
. . . . D IX1^DIK K DIK
|
|
. . I ENFLD=40 D Q ; comments
|
|
. . . D WP^DIE(6914,ENDA_",",40,"A","^TMP($J,""ENCOM"")","ENERR()")
|
|
. . I ENFLD=70 D Q ; spex
|
|
. . . D WP^DIE(6914,ENDA_",",70,"A","^TMP($J,""ENSPEX"")","ENERR()")
|
|
. . I ENVALI']"" S ENVALI=$P($G(^TMP($J,"ENFLD",ENFLD,ENDA)),U)
|
|
. . I ENVALI']"" Q
|
|
. . I ENFLD=2,ENVALI=ENDA Q ; can't be it's own parent
|
|
. . S DA=ENDA,DIE=6914,DR=ENFLD_$S(ENVALI]"":"////^S X=ENVALI",1:"")
|
|
. . D ^DIE K DIE
|
|
. ; did both life expectency and CSN get updated?
|
|
. I $D(^TMP($J,"ENFLD",15)),$D(^TMP($J,"ENFLD",18)) D
|
|
. . ; must redo life expectancy because CSN trigger overwrote
|
|
. . S ENVALI=$P(^TMP($J,"ENFLD",15),U)
|
|
. . I ENVALI']"" Q
|
|
. . S DA=ENDA,DIE=6914,DR="15////^S X=ENVALI"
|
|
. . D ^DIE K DIE
|
|
. ; unlock individual item when not locking as batch
|
|
. I 'ENLOCK("BATCH") L -^ENG(6914,ENDA)
|
|
. W "."
|
|
I $D(^TMP($J,"ENLCK")) D
|
|
. W $C(7),!!,"Warning: Some of the selected equipment could not be"
|
|
. W !,"updated because it was being being edited by another process."
|
|
. W !,"These equipment items will need to be edited to make the"
|
|
. W !,"desired changes. Print the report for more information.",!
|
|
. S DIR("B")="YES"
|
|
S DIR(0)="Y",DIR("A")="Would you like a list of modified equipment"
|
|
D ^DIR K DIR G:$D(DIRUT)!'Y EXIT
|
|
D EN^ENEQMED3
|
|
EXIT ;
|
|
; delete dummy record created for PM data (if any)
|
|
I $G(ENDAT)>90000000000 D
|
|
. ; delete responsible shops to clean up AB x-ref
|
|
. S ENDAPM=0 F S ENDAPM=$O(^ENG(6914,ENDAT,4,ENDAPM)) Q:'ENDAPM D
|
|
. . K DA S DA(1)=ENDAT,DA=ENDAPM,DIK="^ENG(6914,"_ENDAT_",4,"
|
|
. . D ^DIK K DIK
|
|
. ; delete renamining data (wasn't created via FileMan so don't use now)
|
|
. K ^ENG(6914,ENDAT)
|
|
. L -^ENG(6914,ENDAT)
|
|
; unlock selected equipment (if any)
|
|
I $G(ENLOCK("BATCH")) D
|
|
. S ENDA=0
|
|
. F S ENDA=$O(^TMP($J,"ENSEL",ENDA)) Q:'ENDA L -^ENG(6914,ENDA)
|
|
; clean up variables
|
|
K ^TMP($J)
|
|
K %X,%Y,DA,DIC,DIQ,DIWESUB,DR,DUOUT,DTOUT,DIRUT,DIROUT,X,Y
|
|
K ENA,ENASK,ENC,ENCAT,ENCATI,ENDA,ENDAPM,ENDAT,ENDX,ENEDNX
|
|
K ENFA,ENFLD,ENFLDN,ENGOT,ENI,ENL,ENLOCK,ENMAN,ENMANI
|
|
K ENMOD,ENNX,ENPO,ENVALE,ENVALI,ENX,ENXP
|
|
Q
|
|
;ENEQMED2
|