VistA-FOIAVistA/r/LAB_SERVICE-LR-LS/LR7OF3.m

53 lines
3.1 KiB
Mathematica

LR7OF3 ;slc/dcm - Process OBR messages from OE/RR ;8/11/97
;;5.2;LAB SERVICE;**121,187,223,256**;Sep 27, 1994
;
OBR ;Process OBR part of MSG array
;TEST= Ptr to test in file 60
;TESTN= Test Name
;TYPE= Collection Sample Type
;SAMP= Ptr to Collection sample in file 62
;SPEC= Ptr to Specimen in file 61
;URG= Urgency
I '$O(LRXMSG(0)) D
. S TEST=+$P($P(LRXMSG,"|",5),"^",4),TESTN=$P($P(LRXMSG,"|",5),"^",6),TYPE=$$LRACTCOD^LR7OU0($P(LRXMSG,"|",12))
. S SPEC=$S($P($P($P(LRXMSG,"|",5),"^",4),"~",2):$P($P($P(LRXMSG,"|",5),"^",4),"~",2),1:$$LRSPEC^LR7OU0($P(LRXMSG,"|",16)))
. S URG=$$LRURG^LR7OU0($P($P(LRXMSG,"|",28),"^",6)),SAMP=$$LRSAMP^LR7OU0($P(LRXMSG,"|",16))
I $O(LRXMSG(0)) D
. N I,J,X1,CTR
. F CTR=1:1:$L(LRXMSG,"|") S X1(CTR)=$P(LRXMSG,"|",CTR)
. S J=0 F S J=$O(LRXMSG(J)) Q:J<1 D
.. S I=1 I $E(LRXMSG(J))'="|" S X1(CTR)=X1(CTR)_$P(LRXMSG,"|"),I=I+1
.. F I=I:1:$L(LRXMSG(J),"|") S CTR=CTR+1,X1(CTR)=$P(LRXMSG(J),"|",I)
. S TEST=$P(X1(5),"^",4),TESTN=$P(X1(5),"^",6),TYPE=$$LRACTCOD^LR7OU0(X1(12))
. S SPEC=$S($P($P(X1(5),"^",4),"~",2):$P($P(X1(5),"^",4),"~",2),1:$$LRSPEC^LR7OU0(X1(16)))
. S URG=$$LRURG^LR7OU0($P(X1(28),"^",6)),SAMP=$$LRSAMP^LR7OU0(X1(16))
I '$L(TEST) D ACK^LR7OF0("DE",LRXORC,"TEST pointer not sent in message") S LREND=1 Q
I '$L($G(^LAB(60,+TEST,0))) D ACK^LR7OF0("DE",LRXORC,"Invalid Lab test pointer sent from CPRS: "_TEST) S LREND=1 Q
I '$L(TESTN) D ACK^LR7OF0("DE",LRXORC,"Test Name not sent in message") S LREND=1 Q
I '$L(TYPE) D ACK^LR7OF0("DE",LRXORC,"Collection type not sent in message") S LREND=1 Q
I '$L(SAMP) D ACK^LR7OF0("DE",LRXORC,"Sample pointer not sent in message") S LREND=1 Q
I '$L(SPEC) D ACK^LR7OF0("DE",LRXORC,"Specimen not set in file 62: "_SAMP) S LREND=1 Q
I '$L(URG) D ACK^LR7OF0("DE",LRXORC,"Urgency not sent in message") S LREND=1 Q
I LRXTYPE="XO" D Q ;Change order request
. D GET^LR7OF2(.LRXORC,LRXORC)
. Q:'$G(LRORD)
. N TST,FLAG
. S FLAG=0
. I 'LRVERZ F S LRODT=$O(^LRO(69,"C",LRORD,LRODT)) Q:LRODT<1 S LRSN=0 F S LRSN=$O(^LRO(69,"C",LRORD,LRODT,LRSN)) Q:LRSN<1 I $P(^LRO(69,LRODT,1,LRSN,0),"^",3)=SAMP S FLAG=1 D JAB
. I LRVERZ,$D(^LRO(69,LRODT,1,LRSN,0)),$P(^(0),"^",3)=SAMP S FLAG=1 D JAB
. I FLAG=0 D ACK^LR7OF0("XO",LRXORC,"Specimen not found") S LREND=1 Q
I LRXTYPE="NW" D ST Q ;New order request
Q
JAB ;Cancel or Add test
I TYPE=3,$D(^LRO(69,LRODT,1,LRSN,2,"B",+TEST)) D DOIT^LR7OF2(LRODT,LRSN,TEST,LRXORC,$G(LRDUZ),$G(REASON)) Q
I TYPE="A",'$D(^LRO(69,LRODT,1,LRSN,2,"B",+TEST)) D Q
. I $O(^LRO(69,LRODT,1,LRSN,2,0)),$P(^($O(^(0)),0),"^",3) S LREND=1 D ACK^LR7OF0("UX",LRXORC,"Orders have been accessioned, call lab to add tests to the same order.") Q
. S I=$O(^LRO(69,LRODT,1,LRSN,2,99999),-1)+1,^LRO(69,LRODT,1,LRSN,2,I,0)=TEST_"^"_URG,^LRO(69,LRODT,1,LRSN,2,"B",+TEST,I)=""
Q
ST S LRSX=LRSX+1
I $D(^TMP("OR",$J,"LROT",STARTDT,TYPE,SAMP,SPEC,LRSX)) G ST
S ^TMP("OR",$J,"LROT",STARTDT,TYPE,SAMP,SPEC,0)=ORIFN ;_"^"_$S($P($G(^LAB(60,TEST,0)),"^",4)'="CH":1,1:0) ;Setting 2nd piece forces unique order number
S ^TMP("OR",$J,"LROT",STARTDT,TYPE,SAMP,SPEC,LRSX)=TEST_"^"_QUANT
S ^TMP("OR",$J,"LROT",STARTDT,TYPE,SAMP,SPEC,LRSX,1)=URG
Q