141 lines
4.9 KiB
Mathematica
141 lines
4.9 KiB
Mathematica
EC2P96PT ;ALB/GTS/JAP/GT - PATCH EC*2.0*96 Post-Init Rtn ;02/28/2008
|
|
;;2.0; EVENT CAPTURE ;**96**;8 May 96;Build 5
|
|
;
|
|
POST ; entry point
|
|
N ECVRRV
|
|
;* if 725 converted, write message
|
|
; since check inserted in addproc subroutine, patch may be re-installed
|
|
I $$GET1^DID(725,"","","PACKAGE REVISION DATA")["EC*2*96" D
|
|
.D MES^XPDUTL(" ")
|
|
.D MES^XPDUTL("It appears that the EC NATIONAL PROCEDURE")
|
|
.D MES^XPDUTL("file (#725) has already been updated")
|
|
.D MES^XPDUTL("with Patch EC*2*96.")
|
|
.D MES^XPDUTL(" ")
|
|
.D MES^XPDUTL("But the patch may be re-installed...")
|
|
.D MES^XPDUTL(" ")
|
|
D ENTUP
|
|
D F7203
|
|
D KILL1
|
|
Q
|
|
;
|
|
ENTUP ;
|
|
D MES^XPDUTL(" ")
|
|
D BMES^XPDUTL("Updating the National Procedures file (#725)...")
|
|
D MES^XPDUTL(" ")
|
|
;* add new/edit national procedures
|
|
D ADDPROC^EC725U48 ;add new procedures
|
|
D NAMECHG^EC725U48 ;change desription
|
|
D CPTCHG^EC725U49 ;change CPT code
|
|
D INACT^EC725U49 ;inactivate code
|
|
D REACT^EC725U49 ;reactivate code
|
|
;* set vrrv node (file #725)
|
|
S ECVRRV=$$GET1^DID(725,"","","PACKAGE REVISION DATA")
|
|
S ECVRRV=ECVRRV_"^EC*2*96"
|
|
D PRD^DILFD(725,ECVRRV)
|
|
D MES^XPDUTL(" ")
|
|
D BMES^XPDUTL("Update of EC NATIONAL PROCEDURE file (#725)")
|
|
D BMES^XPDUTL(" completed...")
|
|
D MES^XPDUTL(" ")
|
|
Q
|
|
MSGTXT ; Message intro
|
|
;; Please forward this message to your local DSS Site Manager or
|
|
;; Event Capture ADPAC.;; Event Capture ADPAC.
|
|
;;
|
|
;; A review of the EC EVENT CODE SCREENS file (#720.3) was done
|
|
;; after installation of patch EC*2*96 which updated the EC NATIONAL
|
|
;; PROCEDURE file (#725). This message provides the results of that
|
|
;; review.
|
|
;;
|
|
;; The EC EVENT CODE SCREENS file (#720.3) records indicated below
|
|
;; point to an inactive record in the EC NATIONAL PROCEDURE file
|
|
;; (#725) or to an inactive record in the CPT file (#81).
|
|
;;
|
|
;; The user should use the Inactivate Event Code Screens [ECNACT]
|
|
;; option to inactivate the Event Code Screen. If necessary, a new
|
|
;; Event Code Screen can be created using a currently active CPT code
|
|
;; or National Procedure.
|
|
;;
|
|
;;QUIT
|
|
;
|
|
F7203 ;* inspect/report 720.3
|
|
D BMES^XPDUTL("Inspecting EC Event Code Screens file (#720.3)...")
|
|
D BMES^XPDUTL("You will receive a MailMan message regarding file #720.3^ ")
|
|
D BMES^XPDUTL(" ")
|
|
S ZTRTN="F7203Q^EC2P96PT",ZTDESC="File #720.3 Review from EC*2*96",ZTIO=""
|
|
S ZTDTH=$H,ZTREQ="@",ZTSAVE("ZTREQ")="" D ^%ZTLOAD
|
|
Q
|
|
;
|
|
F7203Q ;* background job entry point
|
|
N ECPTR,ECPROCT,EC01,ECSCDA,ECFILE,ECDATA,ECLOC,ECCAT,ECCATNM,ECUNIT,ECNAM,ECPROC,ECINACT,COUNT,TXTVAR
|
|
S COUNT=0 K ^TMP($J,"EC2P96")
|
|
F I=1:1 S TXTVAR=$P($T(MSGTXT+I),";;",2) Q:TXTVAR="QUIT" D LINE(TXTVAR)
|
|
S (EC01,ECPROCT)=0
|
|
F S EC01=$O(^ECJ("B",EC01)) Q:+EC01=0 D
|
|
.S ECPTR=$P(EC01,"-",4),ECSCDA=$O(^ECJ("B",EC01,0))
|
|
.Q:'$D(^ECJ(ECSCDA,0))
|
|
.;ignore any ec screen that has been inactivated
|
|
.Q:+$P(^ECJ(ECSCDA,0),"^",2)
|
|
.S ECFILE=$P(ECPTR,";",2)
|
|
.;ec screens pointing to file #725
|
|
.I ECFILE["EC(725" S ECDATA=$G(^EC(725,$P(ECPTR,";",1),0)) D
|
|
..S ECINACT=$P(ECDATA,U,3)
|
|
..Q:ECINACT=""
|
|
..;ignore if procedure inactivated before this fiscal year
|
|
..Q:(ECINACT<3080401)
|
|
..S Y=ECINACT D DD^%DT S ECINACT=Y
|
|
..S ECLOC=$P(EC01,"-",1),ECUNIT=$P(EC01,"-",2),ECCAT=$P(EC01,"-",3)
|
|
..S ECLOC=$P($G(^DIC(4,ECLOC,0)),U,1),ECUNIT=$P($G(^ECD(ECUNIT,0)),U,1)
|
|
..S:+ECCAT'=0 ECCATNM=$P($G(^EC(726,ECCAT,0)),U,1)
|
|
..S:+ECCAT=0 ECCATNM="None"
|
|
..S ECPROC=$P(ECDATA,U,1)_" ("_$P(ECDATA,U,2)_")"
|
|
..S ECNAM=$P(^ECJ(ECSCDA,0),";",1)
|
|
..D LINE(" ")
|
|
..D LINE(" The National Procedure for the following Event Code")
|
|
..D LINE(" Screen ("_ECNAM_") is inactive or will soon be inactive --")
|
|
..D LINE(" Location: "_ECLOC)
|
|
..D LINE(" Category: "_ECCATNM)
|
|
..D LINE(" DSS Unit: "_ECUNIT)
|
|
..D LINE(" Procedure: "_ECPROC)
|
|
..D LINE(" Inactivation Date: "_ECINACT)
|
|
..S ECPROCT=ECPROCT+1
|
|
.;ec screens pointing to file #81
|
|
.I ECFILE["ICPT" S ECDATA=$G(^ICPT($P(ECPTR,";",1),0)) D
|
|
..S ECINACT=$P(ECDATA,U,4)
|
|
..Q:ECINACT=""
|
|
..S ECLOC=$P(EC01,"-",1),ECUNIT=$P(EC01,"-",2),ECCAT=$P(EC01,"-",3)
|
|
..S ECLOC=$P($G(^DIC(4,ECLOC,0)),U,1),ECUNIT=$P($G(^ECD(ECUNIT,0)),U,1)
|
|
..S:+ECCAT'=0 ECCATNM=$P($G(^EC(726,ECCAT,0)),U,1)
|
|
..S:+ECCAT=0 ECCATNM="None"
|
|
..S ECPROC=$P(ECDATA,U,2)_" ("_$P(ECDATA,U,1)_")",ECNAM=$P(^ECJ(ECSCDA,0),";",1)
|
|
..D LINE(" ")
|
|
..D LINE(" The CPT procedure for the following Event")
|
|
..D LINE(" Code Screen ("_ECNAM_") is inactive --")
|
|
..D LINE(" Location: "_ECLOC)
|
|
..D LINE(" Category: "_ECCATNM)
|
|
..D LINE(" DSS Unit: "_ECUNIT)
|
|
..D LINE(" Procedure: "_ECPROC)
|
|
..S ECPROCT=ECPROCT+1
|
|
I ECPROCT=0 D
|
|
.D LINE(" ")
|
|
.D LINE(" "_ECPROCT_" Event Code Screens were found to be pointing to aninactive")
|
|
.D LINE(" or soon to be inactive procedure in file #725 or file #81.")
|
|
.D LINE(" ")
|
|
D MAIL
|
|
K ^TMP($J,"EC2P96"),I,Y
|
|
Q
|
|
;
|
|
LINE(TEXT) ; Add line to message global
|
|
S COUNT=COUNT+1,^TMP($J,"EC2P96",COUNT)=TEXT
|
|
Q
|
|
;
|
|
MAIL ; Send message
|
|
N XMDUZ,XMY,XMTEXT,XMSUB
|
|
S XMY(DUZ)="",XMDUZ=.5
|
|
S XMSUB="Event Code Screens to Review"
|
|
S XMTEXT="^TMP($J,""EC2P96"","
|
|
D ^XMD
|
|
Q
|
|
KILL1 ;
|
|
K ZTDESC,ZTDTH,ZTIO,ZTREQ,ZTRTN,ZTSAVE("ZTREQ")
|
|
Q
|