HLEVMST ;O-OIFO/LJA - Event Monitor MASTER JOB ;02/04/2004 14:42
;;1.6;HEALTH LEVEL SEVEN;**109**;Oct 13, 1995
;
; Calling STARTJOB always queues a new master job NOW...
;
MSTENV ; Display environment to user...
;
;
; Collect Master Job Information
;
;
; Collect Active Event Monitors
;
;
Q
;
CHECKMST ; Called from outside Event Monitoring, from the Link Manager,
; to see if the master job needs to be started. (See ^HLCSLM.)
; When the Link Manager calls here, two actions potentially occur:
;
; * Check is made whether this CHECKMST code has been run before,
; and if so, how long ago. This check is performed by $$TIMECHK.
; * If never run, or if run more than four hours ago, CHECKMST is run.
;
; CHECKMST checks whether a master job is running, or is properly
; queued. If not, it queues a master job.
;
N LAPSE,LASTDT,LASTIEN,NODE,PAR0,RUNOW,RUNTIME,X
;
QUIT:'$$TIMECHK ;->
;
; Set last check time for later use by $$TIMECHK...
S HLEVLCHK(1)=$$SEC^HLEVMST0($H)
;
; Parameter status check...
S PAR0=$G(^HLEV(776.999,1,0)) Q:PAR0']"" ;->
I $P(PAR0,U,2)'="A" D QUIT ;-> Not ACTIVE...
. D SHOWQUIT("Master job not started. Parameter STATUS is INACTIVE...")
;
; Lapse (since last run) check...
S LAPSE=$P(PAR0,U,3) I LAPSE'>0 D QUIT ;->
. D SHOWQUIT("Master job not started. Master Job Interval not set up...")
; Get IEN for last master job run
S LASTDT=$O(^HLEV(776.2,"B",":"),-1)
S LASTIEN=$O(^HLEV(776.2,"B",+LASTDT,":"),-1)
;
I LASTIEN'>0 D STARTJOB QUIT ;->
S NODE=$G(^HLEV(776.2,+LASTIEN,0))
S X=$P(NODE,U,4) I X="E"!(X="P") D STARTJOB QUIT ;->
S RUNTIME=$P(NODE,U,6) ; Queue time for last run...
S RUNOW=$$RUNEV^HLEVAPI0(RUNTIME,LAPSE+15) ; No start unless 15" overdue
I RUNOW D STARTJOB QUIT ;-> 15" overdue!! So, start master job
D SHOWQUIT("Master job not started. Not time yet...")
;
Q
;
TIMECHK() ; Every loop in the Link Manager code in HLCSLM results in one
; call being made to CHECKMST^HLEVMST. The CHECKMST subroutine in turn
; calls here to ensure that the Event Monitor's master job is running
; properly. However, the CHECKMST subroutine should be run by HLCSLM
; only once every four hours. The code in this subroutine uses
; HLEVLCHK(#) variables to ensure that this every four hour rule is
; followed. (HLEVLCHK is newed at the top of HLCSLM.)
;
; Set the time NOW in seconds...
S HLEVLCHK(0)=$$SEC^HLEVMST0($H)
;
; This is the time of last check. Make sure it exists...
S HLEVLCHK(1)=$G(HLEVLCHK(1))
;
; If no check every made, make a check now...
I HLEVLCHK(1)'>0 QUIT 1 ;->
;
; Set the number seconds between NOW and time of last check...
S HLEVLCHK(3)=HLEVLCHK(0)-HLEVLCHK(1) ; DIFF = NOW - LAST CHECK
;
; If less than 4 hours since last check, quit w/no check...
QUIT:HLEVLCHK(3)<(60*60*4) "" ;->
;
Q 1 ; Check should be made...
;
SHOWQUIT(TXT) QUIT:$D(ZTQUEUED) ;->
W !!,TXT,!
Q
;
STARTJOB ; Start a new job with optional display to screen...
N JOBS
S JOBS=$$NEWMSTR(0,1) QUIT:$D(ZTQUEUED) ;->
W !!,"New master job queued to task# ",+JOBS,"..."
W !,"Entry #",$P(JOBS,U,2)," created in HL7 Monitor Master Job file..."
Q
;
MASTER ; Whenever a master job starts, here's where it's queued...
; HLEVIENM - req
;
N D,D0,DA,DIE,DR,FLD,NOEVCHK,NOPURG,NOW,RES,ZTSKMST
;
S ZTREQ="@",NOW=$$NOW^XLFDT
;
S ZTSKMST=$G(ZTSK) QUIT:ZTSKMST'>0 ;->
;
QUIT:$G(^HLEV(776.2,+$G(HLEVIENM),0))']"" ;->
;
; Check parameter...
I $P($G(^HLEV(776.999,1,0)),U,2)'="A" D QUIT ;->
. F FLD=2,3,8 D UPDFLDM(+HLEVIENM,FLD,NOW)
. D UPDFLDM(+HLEVIENM,4,"A")
;
; Give (possibly just executed) $$NEWMSTR(0) DIE call time to execute...
H 2
;
; Queue next job...
S NEWJOB=$$NEWMSTR(1)
;
; What if job requested to stop?
I $P($G(^HLEV(776.2,+HLEVIENM,0)),U,4)="S" D QUIT ;->
. F FLD=2,3,8 D UPDFLDM(+HLEVIENM,FLD,NOW)
. D UPDFLDM(+HLEVIENM,4,"A")
;
; Mark entry to show it successfully started...
D UPDFLDM(+HLEVIENM,4,"R")
F FLD=3,8 D UPDFLDM(+HLEVIENM,FLD,NOW)
D UPDFLDM(+HLEVIENM,50,"Queued job started at "_$$NOW^XLFDT)
;
; Work starts here...
KILL NOEVCHK
S NOEVCHK=0
D EVENTCHK^HLEVAPI0(+HLEVIENM)
;
; Purge MONITOR and MASTER entries...
D PURGEALL^HLEVUTIL(+HLEVIENM)
;
; Mark ERROR any monitors still RUNNING by not current..
D MARKERR^HLEVAPI3
;
; Done...
D UPDFLDM(+HLEVIENM,2,$$NOW^XLFDT)
D UPDFLDM(+HLEVIENM,4,"F")
D UPDFLDM(+HLEVIENM,50,"Queued job finished at "_$$NOW^XLFDT)
D UPDFLDM(+HLEVIENM,50,"# events checked = "_$G(NOEVCHK))
S RES=""
F S RES=$O(NOEVCHK(RES)) Q:RES']"" D
. S RES(1)=$S(RES="E":" were not queued (too early.)",RES="I":" were not queued (inactivated.)",RES="Q":" were queued to execute.",RES="R":" Previous job still running.",RES="X":" errored, for some reason.",1:" have unknown disposition.")
. I RES="M" S RES(1)=" M code check failed."
. S RES(1)="#"_NOEVCHK(RES)_" Events"_RES(1)
. D UPDFLDM(+HLEVIENM,50,RES(1))
;
Q
;
NEWMSTR(FUTURE,SILENT) ; Create a new master job...
;
; If FUTURE=0, then master job will be queued for NOW...
; If FUTURE=1, then master job will be q'd for CUTMIN in future...
;
N CUTMIN,DA,DIC,DIE,DD,DO,DR,HLEVIENM,X,Y,ZTDESC,ZTDTH,ZTIO,ZTRTN,ZTSK
;
; Should this process be silent?
S SILENT=$S($G(SILENT)>0:1,1:0)
;
; Check parameter...
I $P($G(^HLEV(776.999,1,0)),U,2)'="A" D QUIT "" ;->
. QUIT:$D(ZTQUEUED)!(SILENT) ;->
. W !!,"Exiting! Master job not started. Parameter turned off..."
. H 2
;
; Make master stub entry...
S X=$$NOW^XLFDT,DIC="^HLEV(776.2,",DIC(0)="L"
D FILE^DICN
S HLEVIENM=$S(+Y>0:+Y,1:"") I HLEVIENM'>0 D QUIT "" ;->
. QUIT:$D(ZTQUEUED)!(SILENT) ;->
. W !!,"Exiting! Master job not started. Stub record creation failed..."
. H 2
;
; Get CUTMIN and queue new job...
S CUTMIN=$H ; Default to NOW...
I $G(FUTURE) D
. S CUTMIN=$O(^HLEV(776.999,":"),-1),CUTMIN=$P($G(^HLEV(776.999,+CUTMIN,0)),U,3)
. S CUTMIN=$S(CUTMIN:CUTMIN,1:60) ; Default to 60 minutes between jobs...
. S CUTMIN=$$FMTH^XLFDT($$FMADD^XLFDT($$NOW^XLFDT,0,0,CUTMIN))
S ZTIO="",ZTDTH=CUTMIN,ZTDESC="HL Master Job - Event Monitoring"
S ZTRTN="MASTER^HLEVMST"
S ZTSAVE("HLEVIENM")=""
D ^%ZTLOAD
;
; Store task #, etc...
KILL DA,DD,DIC,DO,X,Y
S DA=+HLEVIENM,DIE=776.2,DR="4///Q;5///"_ZTSK_";6////"_$$HTFM^XLFDT(CUTMIN)_";7////"_+DUZ
D ^DIE
;
I '$D(ZTQUEUED)&('SILENT) D
. W !!,"Master job created. Task# ",ZTSK,", and Event# ",HLEVIENM,"..."
. H 2
;
QUIT $G(ZTSK)_U_HLEVIENM
;
UPDFLDM(HLEVIENM,FLD,VAL) ; Update a specific piece in 776.2...
N D,D0,DA,DI,DIE,DR
;
QUIT:$G(^HLEV(776.2,+$G(HLEVIENM),0))']""!($G(VAL)']"") ;->
;
; Call call here to store one 50 diary entry. (Required that
; FLD=50 and VAL=Text to store on line. Must call here one time
; for every line to be stored.)
I FLD=50 D QUIT ;-> Call call here to store one 50 diary entry
. S NODE=$G(^HLEV(776.2,+HLEVIENM,50,0))
. S:NODE']"" NODE="^776.201^^"
. S CT=$O(^HLEV(776.2,+HLEVIENM,50,":"),-1)+1
. S $P(NODE,U,3)=CT,$P(NODE,U,4)=CT
. S ^HLEV(776.2,+HLEVIENM,50,0)=NODE
. S ^HLEV(776.2,+HLEVIENM,50,+CT,0)=VAL
;
I FLD=51 QUIT ;-> Not allowed!
;
; Store zero node information...
S DA=+HLEVIENM,DIE=776.2,DR=FLD_"///"_VAL
D ^DIE
;
Q
;
STAMPM(HLEVIENM) ; Update TIMESTAMP field in event..
N D,D0,DA,DI,DIE,DR
QUIT:$G(^HLEV(776.2,+$G(HLEVIENM),0))']"" ;->
S DA=+HLEVIENM,DIE=776.2,DR="3////"_$$NOW^XLFDT
D ^DIE
Q
;
PURGEM(HLEVIENM) ; Purge master job entries...
N CUTIME,IENM,LOOPTM,NOPURG,RETHRM
;
; Check parameter...
QUIT:$P($G(^HLEV(776.999,1,0)),U,2)'="A" "" ;->
;
S NOPURG=0
;
; Get retention time (HR) for master job data...
S RETHRM=$O(^HLEV(776.999,":"),-1)
S RETHRM=$P($G(^HLEV(776.999,+RETHRM,0)),U,5)
S RETHRM=$S(RETHRM>0:RETHRM,1:96) ; Default to 96 hours
;
; Cutoff time...
S CUTIME=$$FMADD^XLFDT($$NOW^XLFDT,0,-RETHRM)
;
F S CUTIME=$O(^HLEV(776.2,"B",CUTIME),-1) Q:CUTIME'>0 D
. S IEN=0
. F S IEN=$O(^HLEV(776.2,"B",CUTIME,IEN)) Q:IEN'>0 D
. . QUIT:IEN=HLEVIENM ;-> Don't delete yourself!!
. . S NOPURG=NOPURG+1
. . D PURGEME^HLEVUTIL(+IEN) ; Delete events in master job...
. . D DELETE^HLEVUTIL(776.2,+IEN)
;
Q NOPURG
;
EOR ;HLEVMST - Event Monitor MASTER JOB ;5/16/03 14:42