GMVLAT0 ;HOIFO/YH,FT-DISPLAY LATEST VITALS/MEASUREMENTS FOR A PATIENT ;5/26/05 14:10
;;5.0;GEN. MED. REC. - VITALS;**1,3**;Oct 31, 2002
;
; This routine uses the following IAs:
; #10104 - ^XLFSTR calls (supported)
;
EN1(DFN) ; Entry to extract the latest vitals/measurements for a patient
;called by GETLAT^GMVGETD
N G,GJ,GBLANK,GMVUSER,GMVNUMBR,X,Y
S GJ=0,GBLANK=""
F X="T","P","R","PO2","BP","HT","WT","CVP","CG","PN" I $D(^GMRD(120.51,"C",X)) S GMR(X)=$O(^GMRD(120.51,"C",X,"")),Y=$P($G(^GMRD(120.51,GMR(X),0)),"^") Q:Y=""
K GMRDT,GMRVWT,GMRVHT
S X=""
F S X=$O(GMR(X)) Q:X="" S GMRDATS="" I GMR(X)>0 F GMRDAT=0:0 S GMRDAT=$O(^GMR(120.5,"AA",DFN,+GMR(X),GMRDAT)) Q:$S(GMRDAT'>0:1,GMRDATS>0:1,1:0) D SETDATAR
I '($D(GMRDATA)\10) S GJ=GJ+1,^TMP($J,"GRPC",GJ)="There are no results to report " G Q
F X="T","P","R","PO2","BP","HT","WT","CVP","CG","PN" I $D(GMRDATA(X)) S GMRVDT="",(GMRVDT(1),GMVD)=0 F S GMVD=$O(GMRDATA(X,GMVD)) Q:GMVD'>0 D WRTDT S GMVD(1)=0 F S GMVD(1)=$O(GMRDATA(X,GMVD,GMVD(1))) Q:GMVD(1)'>0 D
. S GMVNUMBR=$P($G(^GMR(120.5,+GMVD(1),0)),U,8)
. Q:GMVNUMBR="" ;RATE cannot be null
.; set flag to indicate RATE is a numeric reading
. S GMVNUMBR=$$NUMBER(GMVNUMBR)
. S GMVUSER=$P($G(^GMR(120.5,+GMVD(1),0)),U,6) ;user ien
. S GMVUSER=$$PERSON^GMVUTL1(GMVUSER) ;user name
. S GJ=GJ+1,^TMP($J,"GRPC",GJ)="",GMRVX(0)=GMRDATA(X,GMVD,GMVD(1)) S GMRVX=X D:GMVNUMBR EN1^GMVSAS0
.S:GMRVDT(1)=0 ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_$S(X="BP":"B/P",X="P":"Pulse",X="R":"Resp.",X="T":"Temp.",X="HT":"Ht.",X="CG":"Circ/Girth",X="WT":"Wt.",X="PO2":"Pulse Ox",X="PN":"Pain",1:X)_":"
.I GMRVDT(1)=0 S GBLANK=$$REPEAT^XLFSTR(" ",13-$L(^TMP($J,"GRPC",GJ))),^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GBLANK_"("_GMRVDT_") " S GMRVDT(1)=1
.S GBLANK=$$REPEAT^XLFSTR(" ",31-$L(^TMP($J,"GRPC",GJ))),^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GBLANK
. I X="T" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)_$S(GMVNUMBR=1:" F ("_$J(+GMRVX(0)-32*5/9,0,1)_" C)",1:"")
.I X="WT" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)_$S(GMVNUMBR=1:" lb ("_$J(GMRVX(0)*.45359237,0,2)_" kg)",1:"") S GMRVWT=GMRVX(0)/2.2
.I X="HT" D
..S GMRVHT=(GMRVX(0)*2.54)/100
..I GMVNUMBR=0 S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0) Q
..S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_$S(GMRVX(0)\12:GMRVX(0)\12_" ft ",1:"")_$S(GMRVX(0)#12:GMRVX(0)#12_" in",1:"")_$S(GMVNUMBR=1:" ("_$J(GMRVX(0)*2.54,0,2)_" cm)",1:"")
..Q
.I X="CG" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)_$S(GMVNUMBR=1:" in ("_$J(+GMRVX(0)/.3937,0,2)_" cm)",1:"")
.I X="CVP" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)_$S(GMVNUMBR=1:" cmH2O ("_$J(GMRVX(0)/1.36,0,1)_" mmHg)",1:"")
.I X="PO2" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)_$S(GMVNUMBR=1:"% ",1:"")
.I X="P"!(X="R")!(X="BP") S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GMRVX(0)
.I X="PN" D S ^TMP($J,"GRPC",GJ)=^(GJ)_GMRVX(0)
..Q:'GMVNUMBR ;not a number
..I GMRVX(0)=0 S GMRVX(0)="0 - No pain" Q
..I GMRVX(0)=99 S GMRVX(0)="99 - Unable to respond" Q
..I GMRVX(0)=10 S GMRVX(0)="Pain class - 10 Worst imaginable pain" Q
..Q
.S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_$S('$D(GMRVX(1)):"",'GMRVX(1):"",1:"*") K GMRVX
.D CHAR
.I X="WT",$G(GMRVWT)>0,$G(GMRVHT)>0 D
..S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_" _"_GMVUSER
..S GJ=GJ+1,GMRVHT(1)=$J(GMRVWT/(GMRVHT*GMRVHT),0,2),^TMP($J,"GRPC",GJ)="Body Mass Index:",GMVUSER="" D
...S GBLANK=$$REPEAT^XLFSTR(" ",29-$L(^TMP($J,"GRPC",GJ))),^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_GBLANK_GMRVHT(1)_$S(GMRVHT(1)>27:"*",1:"")
...Q
..Q
.S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_" "_$S(GMVUSER]"":"_",1:"")_GMVUSER
.Q
Q ; kill variables and quit
K GMRVWT,GMRVHT,GMR,GMVD,GBP,GMRVARY,GMRVDA,GMRDATA,GMVDM,GLIN,GMRZZ
K GMRVDT,GMROUT,%Y,GMRL,GMRDT,DIC,GMRDAT,GMRDATS,GMRSTR,GMRX,GMRVX,POP
Q
SETDATAR ; get record IEN if not marked as entered-in-error
S Y=0
F S Y=$O(^GMR(120.5,"AA",DFN,GMR(X),GMRDAT,Y)) Q:Y'>0!GMRDATS I '$D(^GMR(120.5,Y,2)) D SETNODE
Q
SETNODE ; Set record node
S GMRL=$S($D(^GMR(120.5,Y,0)):^(0),1:"")
S GMRL1=$P(GMRL,"^") ;adding trailing zeros to time if necessary
S $P(GMRL1,".",2)=$P(GMRL1,".",2)_"0000"
S $P(GMRL1,".",2)=$E($P(GMRL1,".",2),1,4)
S $P(GMRL,"^")=GMRL1
K GMRL1
I GMRL'="" S GMRDATA(X,$P(GMRL,"^"),Y)=$P(GMRL,"^",8),GMRDATS=1 I $P($G(^GMR(120.5,Y,5,0)),"^",4)>0 D CHAR^GMVCHAR(Y,.GMRVARY,GMR(X))
Q
WRTDT ;
S GMRVDT=$E(GMVD,4,5)_"/"_$E(GMVD,6,7)_"/"_$E(GMVD,2,3)_"@"_$E($P(GMVD,".",2),1,2)_$S($E($P(GMVD,".",2),3,4)'="":":"_$E($P(GMVD,".",2),3,4),1:"")
Q
CHAR ;
S GMRZZ=$$WRITECH(GMVD(1),.GMRVARY,5) S:GMRZZ'=""&(X'="PO2") GMRZZ="("_GMRZZ_")"
I X="PO2",$P(^GMR(120.5,GMVD(1),0),"^",10)'="" S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_"with supplemental O2" D
. S GPO2=$P(^GMR(120.5,GMVD(1),0),"^",10)
. S ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_" "_$S(GPO2["l/min":$P(GPO2," l/min")_" L/min",1:"")_$S(GPO2["l/min":$P(GPO2," l/min",2),1:GPO2)
. K GPO2
S:GMRZZ'="" ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_" "_GMRZZ K GMRZZ Q
S:$G(GMRZZ)'="" ^TMP($J,"GRPC",GJ)=^TMP($J,"GRPC",GJ)_" "_GMRZZ K GMRZZ
Q
SETBP ;
D SETBP^GMVLATS
Q
WRITECH(GDA,GARRY,GN) ;
; Input data:
; GDA - Pointer to the patient vitals/measurements data file #120.5
; GARRY - qualifier data array for a measurement
; GARRY(GDA,Print order,qualifier data)
; GN - Number of print order to print
N GMRVDA,GDATA
S GDATA="",GMRVDA(1)=0
F S GMRVDA(1)=$O(GARRY(GDA,GMRVDA(1))) Q:GMRVDA(1)'>0!(GMRVDA(1)>GN) S GMRVDA(2)="" F S GMRVDA(2)=$O(GARRY(GDA,GMRVDA(1),GMRVDA(2))) Q:GMRVDA(2)="" D
. S GDATA=GDATA_","_GMRVDA(2)
. Q
I $E(GDATA,1)="," S GDATA=$E(GDATA,2,$L(GDATA)) ;strip off leading comma
Q GDATA
;
NUMBER(GMVRATE) ; Function determines if the RATE has a numeric reading or one
; of the text codes (e.g. REFUSED).
; Returns 0 if GMVRATE has a text code
; 1 if a numeric reading
N GMVYES
S GMVRATE=$G(GMVRATE)
S GMVYES=1
I "REFUSEDPASSUNAVAILABLE"[$$UP^XLFSTR(GMVRATE) S GMVYES=0